Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38426911

RESUMEN

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Sistema de Registros , Estimulación Cardíaca Artificial/efectos adversos
2.
Heart Rhythm ; 21(1): 66-73, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37742991

RESUMEN

BACKGROUND: The Micra AV Coverage with Evidence Development study is a novel analysis of utilization and outcomes associated with Micra AV leadless pacing in US Medicare patients. OBJECTIVE: The purpose of this study was to describe patient characteristics, complications, and outcomes of patients implanted with a Micra AV leadless pacemaker compared with a contemporaneous cohort of patients implanted with a dual chamber transvenous pacemaker. METHODS: Patients implanted with Micra AV (n = 7471) or a dual chamber transvenous pacemaker (n = 107,800) from February 5, 2020, through December 1, 2021, were identified using device registry-linked Medicare claims data. Acute complications were assessed at 30 days, and chronic complications, reinterventions, and all-cause mortality were assessed at 6 months. RESULTS: Patients implanted with Micra AV had higher rates of end-stage renal disease (14.9% vs 2.0%; P < .0001) and overall comorbidity burden (mean Charlson Comorbidity Index 4.9 vs 3.8; P < .0001). There was no difference in the unadjusted rate of complications at 30 days (9.1% vs 8.7%; P = .61), and patients implanted with Micra AV had a significantly lower adjusted rate of complications (8.6% vs 11.0%; P < .0001). At 6 months, patients implanted with Micra AV had significantly lower rates of complications (adjusted hazard ratio 0.50; 95% confidence interval 0.43-0.57; P < .0001) and reinterventions (adjusted hazard ratio 0.46; 95% confidence interval 0.36-0.58; P < .0001). Patients implanted with Micra AV had higher all-cause mortality at 30 days and 6 months, likely because of differences in the underlying risk of mortality. CONCLUSION: Patients implanted with Micra AV had similar rates of complications at 30 days and significantly lower rates of complications and reinterventions at 6 months, despite being sicker than patients implanted with a transvenous pacemaker.


Asunto(s)
Medicare , Marcapaso Artificial , Estados Unidos/epidemiología , Humanos , Anciano , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Prótesis e Implantes , Estimulación Cardíaca Artificial/efectos adversos
3.
Circ J ; 87(12): 1809-1816, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37532552

RESUMEN

BACKGROUND: The Micra leadless pacemaker has demonstrated favorable outcomes in global trials, but its real-world performance and safety in a Japan-specific population is unknown.Methods and Results: Micra Acute Performance (MAP) Japan enrolled 300 patients undergoing Micra VR leadless pacemaker implantation in 15 centers. The primary endpoint was the acute (30-day) major complication rate. The 30-day and 6-month major complication rates were compared to global Micra studies. All patients underwent successful implantation with an average follow-up of 7.23±2.83 months. Compared with previous Micra studies, Japanese patients were older, smaller, more frequently female, and had a higher pericardial effusion risk score. 11 acute major complications were reported in 10 patients for an acute complication rate of 3.33% (95% confidence interval: 1.61-6.04%), which was in line with global Micra trials. Pericardial effusion occurred in 4 patients (1.33%; 3 major, 1 minor). No procedure or device-related deaths occurred. Frailty significantly improved from baseline to follow-up as assessed by Japan Cardiovascular Health Study criteria. CONCLUSIONS: In a Japanese cohort, implantation of the Micra leadless pacemaker had a high success rate and low major complication rate. Despite the Japan cohort being older, smaller, and at higher risk, the safety and performance was in line with global Micra trials.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Femenino , Humanos , Pueblos del Este de Asia , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Derrame Pericárdico/etiología , Resultado del Tratamiento , Masculino , Arritmias Cardíacas/terapia
4.
Europace ; 25(3): 1041-1050, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36757859

RESUMEN

AIMS: This study compares clinical outcomes between leadless pacemakers (leadless-VVI) and transvenous ventricular pacemakers (transvenous ventricular permanent-VVI) in subgroups of patients at higher risk of pacemaker complications. METHODS AND RESULTS: This study is based on the Micra Coverage with Evidence Development (CED) study. Patients from the Micra CED study were considered in a high-risk subgroup if they had a diagnosis of chronic kidney disease Stages 4-5 (CKD45), end-stage renal disease, malignancy, diabetes, tricuspid valve disease (TVD), or chronic obstructive pulmonary disease (COPD) 12 months prior to pacemaker implant. A pre-specified set of complications and reinterventions were identified using diagnosis and procedure codes. Competing risks models were used to compare reinterventions and complications between leadless-VVI and transvenous-VVI patients within each subgroup; results were adjusted for multiple comparisons. A post hoc comparison of a composite outcome of reinterventions and device complications was conducted. Out of 27 991 patients, 9858 leadless-VVI and 12 157 transvenous-VVI patients have at least one high-risk comorbidity. Compared to transvenous-VVI patients, leadless-VVI patients in four subgroups [malignancy, HR 0.68 (0.48-0.95); diabetes, HR 0.69 (0.53-0.89); TVD, HR 0.60 (0.44-0.82); COPD, HR 0.73 (0.55-0.98)] had fewer complications, in three subgroups [diabetes, HR 0.58 (0.37-0.89); TVD, HR 0.46 (0.28-0.76); COPD, HR 0.51 (0.29-0.90)) had fewer reinterventions, and in four subgroups (malignancy, HR 0.52 (0.32-0.83); diabetes, HR 0.52 (0.35-0.77); TVD, HR 0.44 (0.28-0.70); COPD, HR 0.55 (0.34-0.89)] had lower rates of the combined outcome. CONCLUSION: In a real-world study, leadless pacemaker patients had lower 2-year complications and reinterventions rates compared with transvenous-VVI pacing in several high-risk subgroups. TRIAL REGISTRATION: ClinicalTrials.gov ID NCT03039712.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Fallo Renal Crónico , Marcapaso Artificial , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 34(4): 1015-1023, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36807378

RESUMEN

INTRODUCTION: The Micra Coverage with Evidence Development (CED) Study is a novel comparative analysis of Micra (leadless VVI) and transvenous single-chamber ventricular pacemakers (transvenous VVI) using administrative claims data. To compare chronic complications, device reinterventions, heart failure hospitalizations, and all-cause mortality after 3 years of follow-up. METHODS: US Medicare claims data linked to manufacturer device registration information were used to identify Medicare beneficiaries with a de novo implant of either a Micra VR leadless VVI or transvenous VVI pacemaker from March 9, 2017 to December 31, 2018. Unadjusted and propensity score overlap-weight adjusted Fine-Gray competing risk models were used to compare outcomes at 3 years. RESULTS: Leadless VVI patients (N = 6219) had a 32% lower rate of chronic complications and a 41% lower rate of reintervention compared with transvenous VVI patients (N = 10 212) (chronic complication hazard ratio [HR] 0.68; 95% confidence interval [CI], 0.59-0.78; reintervention HR 0.59; 95% CI 0.44-0.78). Infections rates were significantly lower among patients with a leadless VVI (<0.2% vs. 0.7%, p < .0001). Patients with a leadless VVI also had slightly lower rates of heart failure hospitalization (HR 0.90; 95% CI 0.84-0.97). There was no difference in the adjusted 3-year all-cause mortality rate (HR 0.97; 95% CI, 0.92-1.03). CONCLUSION: This nationwide comparative evaluation of leadless VVI versus transvenous VVI de novo pacemaker implants demonstrated that the leadless group had significantly fewer complications, reinterventions, heart failure hospitalizations, and infections than the transvenous group at 3 years, confirming that the previously reported shorter-term advantages associated with leadless pacing persist and continue to accrue in the medium-to-long-term.


Asunto(s)
Insuficiencia Cardíaca , Marcapaso Artificial , Humanos , Anciano , Estados Unidos , Estudios de Seguimiento , Diseño de Equipo , Medicare , Marcapaso Artificial/efectos adversos , Insuficiencia Cardíaca/etiología
6.
J Cardiovasc Electrophysiol ; 34(1): 197-206, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36317470

RESUMEN

INTRODUCTION: Micra atrioventricular (AV) provides leadless atrioventricular synchronous pacing by sensing atrial contraction (A4 signal). Real-world operation and reliability of AV synchrony (AVS) assessment using device data have not been described. The purposes of this study were to (1) assess the correlation between AVS and atrial mechanical sensed-ventricular pacing (AM-VP) percentages in patients with permanent high-degree AV block and (2) report on the real-world effectiveness of Micra AV. METHODS: The correlation between ECG-determined AVS in-clinic and device-collected %AM-VP was assessed using data from 40 patients with high-degree AV block enrolled in the Micra Atrial tRacking using a Ventricular AccELerometer (MARVEL) 2 study. A retrospective analysis to assess continuously-sampled %AM-VP since last session, device programming, and electrical parameters was performed using Micra AV transmissions from the Medtronic CareLink database. Patients with transmissions ≥180 days postimplant were included. RESULTS: Among the 40 MARVEL 2 AV block patients with a median %VP of 99.7%, AVS was highly correlated with AM-VP (median AVS 87.1%, median AM-VP 79.1%; R2 = 0.764, p < .001). The CareLink cohort included 4384 patients programmed to VDD mode. The mean A4 amplitude was 2.3 ± 1.8 m/s2 at implant and 2.3 ± 1.6 m/s2 at 28 weeks. In patients with %VP >90% (n = 1662), the median %AM-VP was 74.7%. For the full cohort, median %VP was 65.6% and median projected battery longevity was 10.5 years. CONCLUSION: In patients with a high pacing burden, %AM-VP provides a reasonable estimation of AVS. The first large real-world analysis of Micra AV patients with >90% VP showed stable atrial sensing over time with a median %AM-VP, a correlate of AVS, of 74.7%.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Estudios Retrospectivos , Reproducibilidad de los Resultados , Estimulación Cardíaca Artificial
7.
Heart Rhythm ; 20(1): 46-54, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36075532

RESUMEN

BACKGROUND: Previous studies demonstrated that accelerometer-based, mechanically timed atrioventricular synchrony (AVS) is feasible using a leadless ventricular pacemaker. OBJECTIVE: The purpose of this study was to determine the performance of a leadless ventricular pacemaker with accelerometer-based algorithms that provide AVS pacing. METHODS: AccelAV was a prospective, single-arm study to characterize AVS in patients implanted with a Micra AV, which uses the device accelerometer to mechanically detect atrial contractions and promote VDD pacing. The primary objective was to characterize resting AVS at 1 month in patients with complete atrioventricular block (AVB) and normal sinus function. RESULTS: A total of 152 patients (age 77 ± 11 years; 48% female) from 20 centers were enrolled and implanted with a leadless pacemaker. Among patients with normal sinus function and complete AVB (n = 54), mean resting AVS was 85.4% at 1 month, and ambulatory AVS was 74.8%. In the subset of patients (n = 20) with programming optimization, mean ambulatory AVS was 82.6%, representing a 10.5% improvement (P <.001). Quality of life as measured by the EQ-5D-3L (EuroQol Five-Dimensions Three-Level questionnaire) improved significantly from preimplant to 3 months (P = .031). In 37 patients with AVB at both 1 and 3 months, mean AVS during rest did not differ (86.1% vs 84.1%; P = .43). There were no upgrades to dual-chamber devices or cardiac resynchronization therapy through 3 months. CONCLUSION: Accelerometer-based mechanical atrial sensing provided by a leadless pacemaker implanted in the right ventricle significantly improves quality of life in a select cohort of patients with AV block and normal sinus function. AVS remained stable through 3 months, and there were no system upgrades to dual-chamber pacemakers.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Fibrilación Atrial/terapia , Estudios Prospectivos , Calidad de Vida , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/métodos
8.
Europace ; 24(7): 1119-1126, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35025987

RESUMEN

AIMS: There is limited information on what clinical factors are associated with the development of pericardial effusion after leadless pacemaker implantation. We sought to determine predictors of and to develop a risk score for pericardial effusion in patients undergoing Micra leadless pacemaker implantation attempt. METHODS AND RESULTS: Patients (n = 2817) undergoing implant attempt from the Micra global trials were analysed. Characteristics were compared between patients with and without pericardial effusion (including cardiac perforation and tamponade). A risk score for pericardial effusion was developed from 18 pre-procedural clinical variables using lasso logistic regression. Internal validation and future prediction performance were estimated using bootstrap resampling. The scoring system was also externally validated using data from the Micra Acute Performance European and Middle East (MAP EMEA) registry. There were 32 patients with a pericardial effusion [1.1%, 95% confidence interval (CI): 0.8-1.6%]. Following lasso logistic regression, 11 of 18 variables remained in the model from which point values were assigned. The C-index was 0.79 (95% CI: 0.71-0.88). Patient risk score profile ranged from -4 (lowest risk) to 5 (highest risk) with 71.8% patients considered low risk (risk score ≤0), 16.6% considered medium risk (risk score = 1), and 11.7% considered high risk (risk score ≥2) for effusion. The median C-index following bootstrap validation was 0.73 (interquartile range: 0.70-0.75). The C-index based on 9 pericardial effusions from the 928 patients in the MAP EMEA registry was 0.68 (95% CI: 0.52-0.83). The pericardial effusion rate increased significantly with additional Micra deployments in medium-risk (P = 0.034) and high-risk (P < 0.001) patients. CONCLUSION: The overall rate of pericardial effusion following Micra implantation attempt is 1.1% and has decreased over time. The risk of pericardial effusion after Micra implant attempt can be predicted using pre-procedural clinical characteristics with reasonable discrimination. CLINICAL TRIAL REGISTRATION: The Micra Post-Approval Registry (ClinicalTrials.gov identifier: NCT02536118), Micra Continued Access Study (ClinicalTrials.gov identifier: NCT02488681), and Micra Transcatheter Pacing Study (ClinicalTrials.gov identifier: NCT02004873).


Asunto(s)
Marcapaso Artificial , Derrame Pericárdico , Ensayos Clínicos como Asunto , Diseño de Equipo , Humanos , Marcapaso Artificial/efectos adversos , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/epidemiología , Derrame Pericárdico/etiología , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento
9.
Heart Rhythm ; 19(2): 228-234, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34757189

RESUMEN

BACKGROUND: Early results from the Micra investigational trial and Micra Post-Approval Registry (PAR) demonstrated excellent safety and device performance; however, outcomes based on anticoagulation (AC) status at implant have not been evaluated. OBJECTIVE: The purpose of this study was to report implant characteristics, perforation rate, and vascular-related events based on perioperative oral AC strategy in patients undergoing Micra implant. METHODS: We compared procedure characteristics, major complications, and vascular events, including pericardial effusion, stratified by any adverse event (including major complications, minor complications, and observations) or major complication only according to AC status in the Micra PAR. RESULTS: Among 1795 patients with AC status available, 585 were not on AC, 795 had AC interrupted, and 415 had AC continued during Micra implant. Non-AC patients tended to be younger, with less history of atrial fibrillation and chronic obstructive pulmonary disease, and more history of dialysis than interrupted and continued patients. The implant success rate was similar for all groups (99.1%-99.8%). Through 30 days postimplant, the overall major complication rate was 3.1% for the non-AC group, 2.6% for the interrupted group, and 1.5% for the continued group. The combined rate for any vascular or pericardial effusion adverse event did not differ significantly among AC strategies (6.5%, 4.8%, and 3.6%, respectively). CONCLUSION: Implant of Micra seems to be safe and feasible regardless of an interrupted or continued periprocedural oral AC strategy, with no increased risk of perforation or vascular complications.


Asunto(s)
Anticoagulantes/administración & dosificación , Marcapaso Artificial , Anciano , Femenino , Humanos , Masculino , Complicaciones Posoperatorias , Diseño de Prótesis , Sistema de Registros
10.
Eur Heart J ; 43(12): 1207-1215, 2022 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-34788416

RESUMEN

AIMS: Clinical trials have demonstrated the safety and efficacy of the Micra leadless VVI pacemaker; however, longer-term outcomes in a large, real-world population with a contemporaneous comparison to transvenous VVI pacemakers have not been examined. We compared reinterventions, chronic complications, and all-cause mortality at 2 years between leadless VVI and transvenous VVI implanted patients. METHODS AND RESULTS: The Micra Coverage with Evidence Development study is a continuously enrolling, observational, cohort study of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted with a leadless VVI pacemaker between March 9, 2017, and December 31, 2018, were identified using Medicare claims data linked to manufacturer device registration data (n = 6219). All transvenous VVI patients from facilities with leadless VVI implants during the study period were obtained directly from Medicare claims (n = 10 212). Cox models were used to compare 2-year outcomes between groups. Compared to transvenous VVI, patients with leadless VVI had more end-stage renal disease (12.0% vs. 2.3%) and a higher Charlson comorbidity index (5.1 vs. 4.6). Leadless VVI patients had significantly fewer reinterventions [adjusted hazard ratio (HR) 0.62, 95% confidence interval (CI) 0.45-0.85, P = 0.003] and chronic complications (adjusted HR 0.69, 95% CI 0.60-0.81, P < 0.0001) compared with transvenous VVI patients. Adjusted all-cause mortality at 2 years was not different between the two groups (adjusted HR 0.97, 95% CI 0.91-1.04, P = 0.37). CONCLUSION: In a real-world study of US Medicare patients, the Micra leadless VVI pacemaker was associated with a 38% lower adjusted rate of reinterventions and a 31% lower adjusted rate of chronic complications compared with transvenous VVI pacing. There was no difference in adjusted all-cause mortality at 2 years.


Asunto(s)
Estimulación Cardíaca Artificial , Marcapaso Artificial , Anciano , Estimulación Cardíaca Artificial/métodos , Estudios de Cohortes , Diseño de Equipo , Estudios de Seguimiento , Humanos , Medicare , Resultado del Tratamiento , Estados Unidos/epidemiología
11.
JAMA Cardiol ; 6(10): 1187-1195, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34319383

RESUMEN

Importance: The safety and efficacy of leadless VVI pacemakers have been demonstrated in multiple clinical trials, but the comparative performance of the device in a large, real-world population has not been examined. Objective: To compare patient characteristics and complications among patients implanted with leadless VVI and transvenous VVI pacemakers. Design, Setting, Participants: The Longitudinal Coverage With Evidence Development Study on Micra Leadless Pacemakers (Micra CED) is a continuously enrolling observational cohort study evaluating complications, utilization, and outcomes of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted between March 9, 2017, and December 1, 2018, were identified and included. All Medicare patients implanted with leadless VVI and transvenous VVI pacemakers during the study period were enrolled. Patients with less than 12 months of continuous enrollment in Medicare prior to leadless VVI or transvenous VVI implant and with evidence of a prior cardiovascular implantable electronic device were excluded, leaving 5746 patients with leadless VVI pacemakers and 9662 patients with transvenous VVI pacemakers. Data were analyzed from May 2018 to April 2021. Exposures: Medicare patients implanted with leadless VVI pacemakers or transvenous VVI pacemakers. Main Outcomes and Measures: The main outcomes were acute (30-day) complications and 6-month complications. Results: Of 15 408 patients, 6701 (43.5%) were female, and the mean (SD) age was 81.0 (8.7) years. Compared with patients with transvenous VVI pacemakers, patients with leadless VVI pacemakers were more likely to have end-stage kidney disease (690 [12.0%] vs 226 [2.3%]; P < .001) and a higher mean (SD) Charlson Comorbidity Index score (5.1 [3.4] vs 4.6 [3.0]; P < .001). The unadjusted acute complication rate was higher in patients with leadless VVI pacemakers relative to transvenous VVI pacemakers (484 of 5746 [8.4%] vs 707 of 9662 [7.3%]; P = .02). However, there was no significant difference in overall acute complication rates following adjustment for patient characteristics (7.7% vs 7.4%; risk difference, 0.3; 95% CI, -0.6 to 1.3; P = .49). Pericardial effusion and/or perforation within 30 days was significantly higher among patients with leadless VVI pacemakers compared with patients with transvenous VVI pacemakers in both unadjusted and adjusted models (unadjusted, 47 of 5746 [0.8%] vs 38 of 9662 [0.4%]; P < .001; adjusted, 0.8% vs 0.4%; risk difference, 0.4; 95% CI, 0.1 to 0.7; P = .004). Patients implanted with leadless VVI pacemakers had a lower rate of 6-month complications compared with patients implanted with transvenous VVI pacemakers (unadjusted hazard ratio, 0.84; 95% CI, 0.68-1.03; P = .10; adjusted hazard ratio, 0.77; 95% CI, 0.62-0.96; P = .02). Conclusions and Relevance: In this study, despite significant differences in patient characteristics, patients in whom a leadless pacemaker was implanted were observed to have higher rates of pericardial effusion and/or perforation but lower rates of other device-related complications and requirements for device revision at 6 months. Understanding the benefits and risks associated with leadless VVI pacemakers compared with transvenous VVI pacemakers can help clinicians and patients make informed treatment decisions.


Asunto(s)
Bradicardia/terapia , Cateterismo Cardíaco/métodos , Marcapaso Artificial , Anciano de 80 o más Años , Bradicardia/mortalidad , Bradicardia/fisiopatología , Causas de Muerte/tendencias , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos , Humanos , Masculino , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Estados Unidos/epidemiología
12.
J Cardiovasc Electrophysiol ; 32(7): 1947-1957, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33928713

RESUMEN

INTRODUCTION: MARVEL 2 assessed the efficacy of mechanical atrial sensing by a ventricular leadless pacemaker, enabling a VDD pacing mode. The behavior of the enhanced MARVEL 2 algorithm during variable atrio-ventricular conduction (AVC) and/or arrhythmias has not been characterized and is the focus of this study. METHODS: Of the 75 patients enrolled in the MARVEL 2 study, 73 had a rhythm assessment and were included in the analysis. The enhanced MARVEL 2 algorithm included a mode-switching algorithm that automatically switches between VDD and ventricular only antibradycardia pacing (VVI)-40 depending upon AVC status. RESULTS: Forty-two patients (58%) had persistent third degree AV block (AVB), 18 (25%) had 1:1 AVC, 5 (7%) had variable AVC status, and 8 (11%) had atrial arrhythmias. Among the 42 patients with persistent third degree AVB, the median ventricular pacing (VP) percentage was 99.9% compared to 0.2% among those with 1:1 AVC. As AVC status changed, the algorithm switched to VDD when the ventricular rate dropped less than 40 bpm. During atrial fibrillation (AF) with ventricular response greater than 40 bpm, VVI-40 mode was maintained. No pauses longer than 1500 ms were observed. Frequent ventricular premature beats reduced the percentage of AV synchrony. During AF, the atrial signal was of low amplitude and there was infrequent sensing. CONCLUSION: The mode switching algorithm reduced VP in patients with 1:1 AVC and appropriately switched to VDD during AV block. No pacing safety issues were observed during arrhythmias.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Marcapaso Artificial , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial , Frecuencia Cardíaca , Humanos
13.
Kidney Int Rep ; 6(1): 56-65, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33426385

RESUMEN

INTRODUCTION: Establishing the frequency and nature of arrhythmias in hemodialysis (HD) is an important step in improving outcomes of these patients. We undertook this systematic review and meta-analysis to characterize arrhythmia frequency in maintenance HD patients. METHODS: We identified studies on arrhythmias in adult patients on maintenance HD detected via implantable loop recorders (ILRs). Studies included were in English and reported ILR-detected arrhythmia incidence in HD patients. Data were extracted by one author using electronic spreadsheets and verified by a second author. Random effects models were used for pooled inferences. The I 2 statistic was used to quantify heterogeneity. RESULTS: Five studies qualified for inclusion (317 patients). The overall estimates for the annualized rate of death and sudden cardiac death (SCD) was 0.14 (95% confidence interval [CI]: 0.11-0.18) and 0.06 (95% CI: 0.03-0.10), respectively. Across all 5 studies, the combined annualized rate of patients experiencing at least 1 bradycardia/asystole event was 0.19 (95% CI: 0.11-0.33) but heterogeneity was high (I 2 = 79.8%). The average annualized rate of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) episodes (0.02, 95% CI: 0.01-0.05) was significantly lower (P < 0.001) than the rate of bradycardia/asystole reported in the same patients. Incidence of atrial fibrillation (AF) varied significantly across the studies (from 0.07 to 0.83 patients per year) reflecting variable definitions (new-onset vs. total number of episodes). CONCLUSION: The incidence of arrhythmias among chronic HD patients is high, with bradycardia/asystole occurring more frequently than ventricular arrhythmias. Additional studies to refine estimates particularly of AF are needed.

14.
J Cardiovasc Electrophysiol ; 32(3): 832-841, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33428248

RESUMEN

BACKGROUND: The feasibility and outcomes of concomitant atrioventricular node ablation (AVNA) and leadless pacemaker implant are not well studied. We report outcomes in patients undergoing Micra implant with concomitant AVNA. METHODS: Patients undergoing AVNA at the time of Micra implant from the Micra Transcatheter Pacing (IDE) Study, Continued Access (CA) study, and Post-Approval Registry (PAR) were included in the analysis and compared to Micra patients without AVNA. Baseline characteristics, acute and follow-up outcomes, and electrical performance were compared between patients with and without AVNA during the follow-up period. RESULTS: A total of 192 patients (mean age 77.4 ± 8.9 years, 72% female) underwent AVNA at the time of Micra implant and were followed for 20.4 ± 15.6 months. AVNA patients were older, more frequently female, and tended to have more co-morbid conditions compared with non-AVNA patients (N = 2616). Implant was successful in 191 of 192 patients (99.5%). The mean pacing threshold at implant was 0.58 ± 0.35 V and remained stable during follow-up. Major complications within 30 days occurred more frequently in AVNA patients than non-AVNA patients (7.3% vs. 2.0%, p < .001). The risk of major complications through 36-months was higher in AVNA patients (hazard ratio: 3.81, 95% confidence interval: 2.33-6.23, p < .001). Intermittent loss of capture occurred in three AVNA patients (1.6%), all were within 30 days of implant and required system revision. There were no device macrodislodgements or unexpected device malfunctions. CONCLUSION: Concomitant AVN ablation and leadless pacemaker implant is feasible. Pacing thresholds are stable over time. However, patient comorbidities and the risk of major complications are higher in patients undergoing AVNA.


Asunto(s)
Nodo Atrioventricular , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Nodo Atrioventricular/cirugía , Femenino , Humanos , Masculino , Sistema de Registros , Resultado del Tratamiento
15.
JACC Clin Electrophysiol ; 7(4): 502-512, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33358666

RESUMEN

OBJECTIVES: This study sought to formulate a predictive model for describing the long-term electrical performance of Micra (Medtronic, Mounds View, Minnesota). BACKGROUND: The Micra leadless pacemaker is an alternative ventricular pacing option that avoids the pitfalls of transvenous leads. However, well-defined metrics to predict the long-term electrical performance of the device are lacking. METHODS: We identified all patients who underwent successful Micra implantation enrolled in the investigational device exemption study, continued access study, or post-approval registry with complete 1-year post-implantation data or system revision due to elevated thresholds (N = 1,843). The analysis endpoint was an elevated pacing capture threshold (PCT) at ≥12 months post-implantation, defined as ≥2.0 V at 0.24 ms or an increase of ≥1.5 V from implantation or need for system revision due to elevated thresholds at ≤12 months post-implantation. We evaluated for univariate and multivariate associations between patient and device characteristics at implantation and for elevated thresholds at 12 months. RESULTS: Among the total cohort, 75 patients (4.1%) had elevated thresholds at 12 months; of these, 13 required system revisions. Predictors associated with elevated thresholds in univariate analysis included the total number of deployments (excluded from the multivariable model), impedance and PCT at implantation, male sex, history of diabetes, and ischemic cardiomyopathy. Multivariable regression modeling found that male sex, history of diabetes, implantation PCT of ≥2 V, and impedance of <800 Ω were independent predictors of elevated PCT at 12 months (all p < 0.05). CONCLUSION: A history of diabetes, male sex, elevated PCT, and low impedance at implantation were independent predictors of elevated thresholds at 12 months. These metrics represent the foundation of a simple tool to aid in procedural decision making.


Asunto(s)
Marcapaso Artificial , Catéteres Cardíacos , Humanos , Masculino , Estudios Prospectivos , Sistema de Registros , Resultado del Tratamiento
16.
Heart Rhythm ; 17(12): 2056-2063, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32763431

RESUMEN

BACKGROUND: The Micra transcatheter pacemaker is a safe and effective alternative to transvenous permanent pacemakers (TV-PPMs). However, the safety profile and mortality outcomes of Micra implantation in patients deemed poor candidates for TV-PPM are incompletely understood. OBJECTIVE: The purpose of this study was to evaluate safety and all-cause mortality in patients undergoing Micra implantation stratified by whether they were precluded for therapy with a TV-PPM. METHODS: Patients from the Micra clinical trials were divided into groups on the basis of whether the implanter considered the patient to be precluded from receiving a TV-PPM. Micra groups were compared with one another as well as with a historical cohort of patients who received a single-chamber TV-PPM. RESULTS: A total of 2817 patients underwent a Micra implantation attempt, of whom 546 (19%) patients deemed ineligible for TV-PPM implantation for reasons such as venous access issues or prior device infections. Both acute mortality (2.75% vs 1.32%; P=.022) and total mortality at 36 months (38.1% vs 20.6%; P<.001) were significantly higher in the precluded group than in the nonprecluded group. Mortality was similar among nonprecluded patients and patients implanted with a TV-PPM. The major complication rate through 36 months was similar between the 2 Micra groups (3.81% vs 4.30%; P=.40). CONCLUSION: All-cause mortality is higher in Micra patients deemed ineligible for TV-PPM implantation than in nonprecluded Micra patients and those who received a TV-PPM, in part related to a higher incidence of chronic comorbidities in these patients. The overall major complication rate was low and did not differ by preclusion status. CLINICAL TRIAL REGISTRATION: Micra Post-Approval Registry ClinicalTrials.gov identifier: NCT02536118; Micra Continued Access Study ClinicalTrials.gov identifier: NCT02488681; Micra Transcatheter Pacing Study ClinicalTrials.gov identifier: NCT02004873; Medtronic Product Surveillance Registry ClinicalTrials.gov identifier: NCT01524276.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial , Sistema de Registros , Anciano , Arritmias Cardíacas/epidemiología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Morbilidad/tendencias , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
17.
Heart Rhythm ; 17(12): 2037-2045, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32717315

RESUMEN

BACKGROUND: The MARVEL (Micra Atrial TRacking Using a Ventricular AccELerometer) 2 study assessed the efficacy of atrioventricular (AV) synchronous pacing with a Micra leadless pacemaker. Average atrioventricular synchrony (AVS) was 89.2%. Previously, low amplitude of the Micra-sensed atrial signal (A4) was observed to be a factor of low AVS. OBJECTIVE: The purpose of this study was to identify predictors of A4 amplitude and high AVS. METHODS: We analyzed 64 patients enrolled in MARVEL 2 who had visible P waves on electrocardiogram for assessing A4 amplitude and 40 patients with third-degree AV block for assessing AVS at rest. High AVS was defined as >90% correct atrial-triggered ventricular pacing. The association between clinical factors and echocardiographic parameters with A4 amplitude was investigated using a multivariable model with lasso variable selection. Variables associated with A4 amplitude together with premature ventricular contraction burden, sinus rate, and sinus rate variability (standard deviation of successive differences of P-P intervals [SDSD]) were assessed for association with AVS. RESULTS: In univariate analysis, low A4 amplitude was inversely related to atrial function assessed by E/A ratio and e'/a' ratio, and was directly related to atrial contraction excursion (ACE) and atrial strain (Ɛa) on echocardiography (all P ≤.05). The multivariable lasso regression model found coronary artery bypass graft history, E/A ratio, ACE, and Ɛa were associated with low A4 amplitude. E/A ratio and SDSD were multivariable predictors of high AVS, with >90% probability if E/A <0.94 and SDSD <5 bpm. CONCLUSION: Clinical parameters and echocardiographic markers of atrial function are associated with A4 signal amplitude. High AVS can be predicted by E/A ratio <0.94 and low sinus rate variability at rest.


Asunto(s)
Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/métodos , Ventrículos Cardíacos/fisiopatología , Marcapaso Artificial , Adulto , Anciano , Anciano de 80 o más Años , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Ecocardiografía , Electrocardiografía , Femenino , Estudios de Seguimiento , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
19.
J Cardiovasc Electrophysiol ; 31(6): 1289-1297, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32270538

RESUMEN

INTRODUCTION: The VICTORY AF Study was designed to evaluate the risk of the procedure and/or device-related strokes in patients with PersAF on warfarin undergoing ablation with a phased radiofrequency (RF) system. METHODS: The VICTORY AF trial was a prospective, multicenter, single-arm, investigational study. PersAF patients on vitamin K antagonism without major structural heart disease or history of stroke/transient ischemic attack undergoing phased RF ablation for atrial fibrillation (AF) were included. The primary outcome was the incidence of the procedure and/or device-related stroke within 30 days of the ablation by a board-certified neurologist's assessment. The secondary outcomes were an acute procedural success, 6 months effectiveness (defined as the reduction in AF/atrial flutter episodes lasting ≥10 minutes by 48-hour Holter 6 months postablation) and the number of patients with pulmonary vein (PV) stenosis. RESULTS: A total of 129 (108 PersAF, 21 long-standing PersAF) patients were treated (mean age: 60.6 ± 7.7; 79.8% male, 54.3% CHA2Ds2-VASc score ≥ 2). Two nondisabling strokes were reported (1.6%); one before discharge and the second diagnosed at the 30-day visit. Due to slow enrollment, the study was terminated before reaching the 95% one-sided upper confidence boundary for stroke incidence. Acute procedural success was 93.8%, and at 6 months, 72.8% of patients demonstrated ≥90% reduction in AF burden, 78.9% were off all antiarrhythmic drugs. There were no patients with PV stenosis of greater than 70%. CONCLUSIONS: VICTORY AF demonstrated a 1.6% incidence of stroke in PersAF undergoing ablation with a phased RF system which did not meet statistical confidence due to poor enrollment. The secondary outcomes suggest comparable efficacy to phased RF in the tailored treatment of permanent AF trial. Rigorous clinical evaluation of the stroke risk of new AF ablation technologies as well as restriction to Vitamin K antagonist anticoagulation appears to be unachievable goals in a clinical multicenter IDE trial of AF ablation in the current era.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Electrodos , Accidente Cerebrovascular Hemorrágico/epidemiología , Accidente Cerebrovascular Isquémico/epidemiología , Potenciales de Acción , Anciano , Anticoagulantes/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Femenino , Frecuencia Cardíaca , Accidente Cerebrovascular Hemorrágico/diagnóstico , Accidente Cerebrovascular Hemorrágico/prevención & control , Humanos , Incidencia , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/prevención & control , Masculino , Persona de Mediana Edad , América del Norte/epidemiología , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Warfarina/uso terapéutico
20.
Heart Rhythm ; 17(8): 1393-1397, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32247833

RESUMEN

Pacemaker-related infections remain a constant concern due to increased risk of patient morbidity and mortality. Although transvenous pacemakers are expected to have an infection rate ranging from 0.77% to 2.08%, no cases of leadless pacemaker infection have been reported in clinical trials enrolling more than 3000 patients. Many potential reasons why leadless pacemakers may be resistant to infection include the absence of a subcutaneous pocket and leads, reduced skin and glove contact, size, location, and device material. This review summarizes the current state of evidence regarding the apparent infection resistance of leadless pacemakers.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/métodos , Sistema de Conducción Cardíaco/fisiopatología , Marcapaso Artificial , Arritmias Cardíacas/fisiopatología , Diseño de Equipo , Humanos